Installation Procedure
- Install 2 mode valve gear (1).
- Make sure that mode valve gears of mode valve levers (1) are fitted as shown in graphic above.
NOTE: The mode valve gear can only be fitted in one position. The mode valve gears have to be fitted to the according mode valve levers in figured position. The ventilation dampers have to be in middle position.
- Install mode control cam (1).
NOTE: The mode control cam can only be fitted in one position.
- Install instrument panel tie bar (2).
CAUTION: Refer to Fastener Caution .
- Install 4 instrument panel tie bar bolts (3, 4) and tighten to 22 N.m (17 lb ft).
- Install 2 instrument panel tie bar nuts (1) and tighten to 9 N.m (80 lb in).
- Install instrument panel wiring harness (2) from instrument panel tie bar (1).
Courtesy of GENERAL MOTORS COMPANY
Connect electrical connectors.
- Install instrument panel assembly. Refer to Instrument Panel Assembly Replacement .