Exhaust Gas Recirculation Valve Installation
WARNING: This page is about a different variant/trim than selected.
- Clean all sealing surfaces.
- Install the closing plate (1).
- Install the 4 closing plate bolts (2) and tighten in two passes:CAUTION: Refer to Fastener Caution .
- First pass to 3.5 N.m (31 lb in).
- Final pass to an additional 10 N.m (89 lb in).
- Install the exhaust gas recirculation valve flat washer (5).
- Install the exhaust gas recirculation valve (3).
- Install the 2 exhaust gas recirculation valve bolts (4) and tighten in two passes:
- First pass to 6 N.m (53 lb in).