LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2008 >> Optra5 LT, Automatic >> Repair and Diagnosis >> Transmission >> Hydraulic Diagrams >> Automatic Transaxle - ZF 4HP 16 - Service, Overhaul, Removal & Installation, Troubleshooting & Diagnosis >> Transmission Fluid Cooler Hose/Pipe Replacement >> Installation Procedure

Installation Procedure

    Fig 1: Identifying Inlet Pipes
    GM1290944Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice .
  1. Install the inlet pipe assembly and the assembly bolts.

    Tighten:  Tighten the inlet pipe bolts to 35 N.m (26 lb ft)  .

  2. Fig 2: Identifying Outlet Pipes
    GM1290932Courtesy of GENERAL MOTORS CORP.
  3. Install the outlet pipe assembly and the assembly bolts.

    Tighten:  Tighten the outlet pipe bolts to 35 N.m (26 lb ft)  .

  4. Refill the transaxle fluid. Refer to Transmission Fluid Draining .
  5. Install the engine cover. Refer to Engine Cover Replacement .
  6. Connect the negative battery cable.