LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2008 >> Optra5 LT, Automatic >> Repair and Diagnosis >> Transmission >> Hydraulic Diagrams >> Automatic Transaxle - ZF 4HP 16 - Service, Overhaul, Removal & Installation, Troubleshooting & Diagnosis >> Park or Neutral - Engine Running >> Line Pressure Control Valve >> Notes

Line Pressure Control Valve: Notes

The line pressure control valve sets the general pressure level in the valve body. When the gearshifts are not taking place, the line pressure varies between 2 levels, depending on the turbine torque. The line pressure increases steadily over time, but only to the limit point. When pressure reaches that point, excess oil drains back into the oil sump.