Tools Required
- J 43600 Air Conditioning Service Center
- J 45268 Flush Adapter Kit
- J 41447 Leak Detection Dye
- J 41459 Leak Detection Dye Injector
- J 42220
Universal 12V Leak Detection Lamp
Important: Flushing with the ACR 2000 is not intended to remove metal from the A/C system.
Flushing is intended to remove the following:
- Contaminated PAG oil
- Desiccant, following a desiccant bag failure
- Overcharge of PAG oil
- Refrigerant contamination
Important: Warmer engine or ambient temperature decreases the refrigerant recovery time during the A/C flush procedure.
- Recover the refrigerant. Refer to REFRIGERANT RECOVERY AND RECHARGING .
- Remove the orifice tube. Refer to EXPANSION (ORIFICE) TUBE REPLACEMENT .
- Connect the A/C lines with the orifice tube removed.
- Remove the A/C compressor. Refer to COMPRESSOR REPLACEMENT (2.2L) or COMPRESSOR REPLACEMENT (4.3L) .
- Install the J 45268-3 to the A/C compressor hose assembly.
- Forward flow refrigerant flushing is recommended for contaminated refrigerant or PAG oil.
Perform the following procedure:
Important: The filter inside the J 45268-1 is serviceable. Remove and discard the check valve from the filter.
- 6.1 Service the filter with ACDelco P/N GF 470, before each flush.
Connect the J 45268-1 flush filter to the suction port of the J 45268-3 flush adapter.
- 6.2 Connect the blue hose from the J 43600 to the J 45268-1 flush filter adapter.
- 6.3 Connect the red hose from the J 43600 to the J 45268-3.
- 6.1 Service the filter with ACDelco P/N GF 470, before each flush.
- Reverse flow refrigerant flushing is recommended for desiccant bag failure only.
Perform the following procedure and replace the accumulator when the flush is complete:
Important: The filter inside the J 45268-1 is serviceable. Remove and discard the check valve from the filter.
- 7.1 Service the filter with ACDelco P/N GF 470, before each flush.
Connect the J 45268-1 flush filter to the discharge port of the J 45268-3 flush adapter.
- 7.2 Connect the blue hose from the J 43600 to the J 45268-1 flush filter adapter.
- 7.3 Connect the red hose from the J 43600 to the suction port of the J 45268-3.
- 7.1 Service the filter with ACDelco P/N GF 470, before each flush.
- Flush the A/C system. Follow the instructions supplied with the J 43600
.
Close the valve on the external refrigerant tank, before starting the flush process.
NOTE: Refer to FASTENER NOTICE in Cautions and Notices. - Remove the J 45268-3 from the A/C compressor hose assembly.
- Remove the A/C compressor drain plug.
- Drain the PAG oil from the A/C compressor.
- Rotate the compressor input shaft to assist in draining the PAG oil from the compressor.
- Install the A/C compressor drain plug.
Tighten
Tighten the drain plug to 20 N.m (15 Ib. ft).
- If replacing the A/C compressor after flushing the system, perform the following:
- Determine if the new service compressor is shipped with PAG oil. Refer to REFRIGERANT SYSTEM CAPACITIES .
- If the service compressor is shipped with PAG oil, DO NOT drain the new PAG oil from the compressor.
- Deduct the amount of PAG oil shipped with the service compressor from the amount of PAG oil listed in the capacities table. Refer to REFRIGERANT SYSTEM CAPACITIES . Add the calculated amount to the compressor, as needed.
- If the service compressor is shipped dry, no calculation is required. Add the total system capacity of PAG oil to the compressor. Refer to REFRIGERANT SYSTEM CAPACITIES .
- Install the A/C compressor. Refer to COMPRESSOR REPLACEMENT (2.2L) or COMPRESSOR REPLACEMENT (4.3L) .
- Inspect the orifice tube for debris. Clean or replace as needed.
- Install the orifice tube. Refer to EXPANSION (ORIFICE) TUBE REPLACEMENT .
- Evacuate and recharge the A/C system. Refer to REFRIGERANT RECOVERY AND RECHARGING .
Important: Flushing will remove all the PAG oil from the A/C system.
- Add the total system capacity of PAG oil to the A/C system. Refer to REFRIGERANT SYSTEM CAPACITIES .
Important: Flushing will remove the fluorescent leak detection dye from the A/C system.
- Add one bottle of J 41447 using the J 41459 .
- Leak test the fittings using the J 42220 .