Test Description
WARNING: This page is about a different car, the 2004 Chevrolet Corvette. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers on the diagnostic table.
- 3: Tests for the proper operation of the circuit in the high voltage range.
- 4: Tests for the proper operation of the circuit in the low voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to voltage.
DTC B0332, B0333, B0337, or B0338
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views |
||||
| 1 | Did you perform the HVAC Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 |
|
0.09-4.90 V | Go to Diagnostic Aids | Go to Step 3 |
| 3 |
|
4.90 V | Go to Step 4 | Go to Step 5 |
| 4 |
|
0.09 V | Go to Step 8 | Go to Step 6 |
| 5 | Test the signal circuit of the appropriate air temperature sensor for a short to ground. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 9 |
| 6 | Test the signal circuit of the appropriate air temperature sensor for a short to voltage, a high resistance, or an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 7 |
| 7 | Test the low reference circuit of the appropriate air temperature sensor for a high resistance or an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 9 |
| 8 | Inspect for poor connections at the harness connector of the appropriate air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 10 |
| 9 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 12 | Go to Step 11 |
| 10 | Replace the appropriate air temperature sensor. Refer to Ambient Air Temperature Sensor Replacement or Inside Air Temperature Sensor Replacement . Did you complete the replacement? |
- | Go to Step 12 | - |
| 11 |
IMPORTANT:
Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement .Did you complete the replacement? |
- | Go to Step 12 | - |
| 12 |
|
- | Go to Step 2 | System OK |