Blower Motor Inoperative - Auxiliary (VIN 6 excluding Envoy XUV)
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2004 Oldsmobile Bravada, 2004 GMC Envoy XUV, 2004 GMC Envoy XL, 2004 GMC Envoy, and 2004 Chevrolet TrailBlazer. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Inoperative - Auxiliary (VIN 6 excluding Envoy XUV)
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary blower motor is inoperative in all speed positions from both the front and rear controls. |
||||
| 1 | Did you perform the HVAC Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 |
|
- | Go to Blower Motor Malfunction - Auxiliary (VIN 6 excluding Envoy XUV) or Blower Motor Malfunction - Auxiliary (VIN 3 including Envoy XUV) | Go to Step 3 |
| 3 |
|
- | Go to Blower Motor Malfunction - Auxiliary (VIN 6 excluding Envoy XUV) or Blower Motor Malfunction - Auxiliary (VIN 3 including Envoy XUV) | Go to Step 4 |
| 4 |
|
- | Go to Step 5 | Go to Step 6 |
| 5 |
|
- | Go to Step 12 | Go to Step 7 |
| 6 | Test the auxiliary HVAC enable control circuit of the front auxiliary blower motor switch for a short to ground. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 18 | Go to Step 14 |
| 7 | Test the battery positive voltage circuit of the auxiliary blower motor control processor for an open, high resistance or short to ground. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 18 | Go to Step 8 |
| 8 | Test the ground circuit of the auxiliary blower motor control processor for an open or high resistance. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 18 | Go to Step 9 |
| 9 |
IMPORTANT:
Ensure that the auxiliary blower motor control processor connector and the auxiliary HVAC control module connectors are connected during this step in order to avoid misdiagnosis.
|
Low 6 V Med 4 V High 2.5 V Off Battery Voltage | Go to Step 11 | Go to Step 10 |
| 10 | Test the auxiliary blower motor speed control circuit of the auxiliary HVAC control module for an open or a short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 18 | Go to Step 13 |
| 11 | Test the auxiliary blower motor speed control circuit of the auxiliary HVAC control module for a short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 18 | Go to Step 14 |
| 12 | Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 18 | Go to Step 15 |
| 13 | Inspect for poor connections at the harness connector of the auxiliary blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 18 | Go to Step 16 |
| 14 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 18 | Go to Step 17 |
| 15 | Replace the auxiliary blower motor. Refer to Blower Motor Replacement - Auxiliary (Rear Auxiliary)
or Blower Motor Replacement - Auxiliary (Front Auxiliary)
in Heating, Ventilation and Air Conditioning. Did you complete the replacement? |
- | Go to Step 18 | - |
| 16 | Replace the auxiliary blower motor control processor. Refer to Blower Motor Processor Replacement - Auxiliary . Did you complete the replacement? |
- | Go to Step 18 | - |
| 17 |
IMPORTANT:
Perform the recalibration procedure for the auxiliary HVAC control module. Replace the auxiliary HVAC control module. Refer to HVAC Control Module Replacement - Auxiliary .Did you complete the replacement? |
- | Go to Step 18 | - |
| 18 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 2 |