TXV Air Conditioning (A/C) System Diagnosis (Reference Table)
WARNING: This page is about a different car, the 2004 Pontiac Vibe. However, it is still accessible from the selected car via links, so may be relevant.
TXV Air Conditioning (A/C) System Diagnosis (Reference Table)
| Symptom | Correction | ||||
|---|---|---|---|---|---|
| Low Side Pressure | High Side Pressure | ||||
| 150-300 kPa (21-43 psi) |
1275-1670 kPa (185-244 psi) |
Normal | |||
| Vacuum | 500-600 kPa (71-85 psi) |
|
|||
| Normal to vacuum | Normal to 690-980 kPa (100-142 psi) |
The expansion valve is frozen due to moisture in the system, temporarily shutting down the refrigeration cycle. Replace the expansion valve and the receiver dryer, and evacuate and recharge the system. Refer to the following: | |||
| 50-100 kPa (4-14 psi) |
690-980 kPa (100-142 psi) |
Insufficient refrigerant in system. Leak test the system, repair and recharge. Refer to Leak Testing and Refrigerant Recovery and Recharging . | |||
| 400-600 kPa (57-85 psi) |
690-980 kPa (100-142 psi) |
Internal leak in compressor. Replace the compressor. Refer to Compressor Replacement . | |||
| 250-300 kPa (36-43 psi) |
1960-2450 kPa (285-355 psi) |
|
|||
| 300-400 kPa (43-57 psi) |
1960-2450 kPa (285-355 psi) |
|
|||
| Normal to low | Low | Low side restriction. Inspect for a kinked tube/hose, or a clogged suction screen. | |||
| Normal to low | Normal to high | High side restriction. Visually inspect for frost spot. Feel along tubing for temperature change. | |||
| Center Outlet Air Temperature Above Specifications |
|
||||
| Center Outlet Air Temperature Below Specifications |
|
||||