LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2002 >> Blazer 4D Utility, 4WD, Part Time >> Repair and Diagnosis >> External Pages >> Different car >> Section 1336 (Door System, Mirror System & Window System) >> Diagnostic Information and Procedures >> Door Ajar Indicator Malfunction

Door Ajar Indicator Malfunction

WARNING: This page is about a different car, the 2004 Pontiac Vibe. However, it is still accessible from the selected car via links, so may be relevant.
Door Ajar Indicator Malfunction

Step Action Yes No
Schematic Reference: Door Lock/Indicator Schematics 
Connector End View Reference: Power Door Systems Connector End Views 
1 Did you review the Power Door system Description and Operation? Go to Step 2  Go to Diagnostic Starting Point - Doors 
2 Disable the dome lamp override switch.
Is the dome lamp or the door ajar indicator always on?
Go to Dome Lamps Always On in Lighting Systems Go to Step 3 
3 Open each door individually while observing the dome lamps.
Does the dome lamp illuminate with each door?
Go to Step 4  Go to Dome Lamps Inoperative in Lighting Systems
4
  1. Access the Instrument Panel cluster connector.
  2. With the doors closed, back probe the door ajar indicator control circuit with a test lamp that is connected to a good ground.
Does the test lamp illuminate?
Go to Step 5  Go to Step 6 
5 Inspect for poor connections at the I/P cluster connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 10  Go to Step 9 
6 Test for a short to ground in the door ajar indicator control circuit between the Multifunction alarm module and the I/P cluster. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 10  Go to Step 7 
7 Inspect for poor connections at the multifunction alarm module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.
Did you find and correct the condition?
Go to Step 10  Go to Step 8 
8 Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement in Instrument Panel, Gages and Console.
Did you complete the replacement?
Go to Step 10  -
9 Replace the IPC. Refer to Instrument Panel Cluster (IPC) Replacement in Instrument Panel, Gages and Console.
Did you complete the replacement?
Go to Step 10  -
10 Operate the system in order to verify the repair.
Did you correct the condition?
System OK Go to Step 2