LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2002 >> Blazer 4D Utility, 4WD, Part Time >> Repair and Diagnosis >> External Pages >> Different car >> Section 1326 (Instrument Panel System Displays, Gauges And Console) >> Diagnostic Information and Procedures >> Outside Air Temperature Display Inaccurate or Inoperative

Outside Air Temperature Display Inaccurate or Inoperative

WARNING: This page is about a different car, the 2004 Pontiac Vibe. However, it is still accessible from the selected car via links, so may be relevant.
Outside Air Temperature Display Inaccurate or Inoperative

Step Action Yes No
Schematic Reference:  Instrument Cluster Schematics  
1 Did you review the Instrument Cluster Description and perform the necessary inspections? Go to Step 2  Go to Symptoms - Lighting Systems
2 Verify the outside temperature display is inaccurate or inoperative.
Does the system operate normally?
Go to Testing for Intermittent Conditions and Poor Connections Go to Step 3 
3 Measure the resistance between cavity 1 and 2 of the Ambient Air Temperature Sensor. Refer to Ambient Air Temperature Sensor Resistance  for proper resistance specifications.
Is resistance within specs?
Go to Step 4  Go to Step 11 
4 With the ignition in the ON position. Test cavity 1 of the ambient air temperature sensor harness connector for a 5 volt reference signal. Refer to Circuit Testing in Wiring Systems.
Is the voltage present?
Go to Step 5  Go to Step 6 
5 Test cavity 2 of the ambient temperature sensor harness connector for continuity to ground. Refer to Circuit Testing in Wiring Systems.
Is a ground present?
Go to Step 10  Go to Step 7 
6 With the ignition in the ON position. Test cavity 38 of the Instrument panel cluster harness connector for a 5 volt reference signal.Refer to Circuit Testing in Wiring Systems.
Is the voltage present?
Go to Step 8  Go to Step 10 
7 Test cavity 39 of the Instrument panel cluster harness connector for continuity to ground.
Is a ground present?
Go to Step 9  Go to Step 10 
8 Repair the open or high resistance in 5 volt referance circuit between cavity 38 of the I/P cluster and caity 1 of the ambient air temperature sensor. Refer to Wiring Repairs in Wiring Systems.
Did you complete the repair?
Go to Step 12  -
9 Repair the open or high resistance in the ambient temperature sensor ground circuit between cavity 39 of the I/P cluster and cavity 2 of the ambient temperature sensor Refer to Wiring Repairs in Wiring Systems.
Did you complete the repair?
Go to Step 12  -
10 Replace the Instrument Panel Cluster. Refer to Instrument Panel Cluster (IPC) Replacement 
Did you complete the replacement?
Go to Step 12  -
11 Replace the ambient air temperature sensor.
Did you complete the repair?
Go to Step 12  -
12 Operate the system in order to verify the repair.
Did you correct the condition?
System OK Go to Step 3