Vacuum Pump Installation
| Callout | Component Name |
|---|---|
| 1 | Vacuum Pump Gasket
NOTE:
Must use NEW gasket when installing vacuum pump. |
| 2 | Vacuum Pump Assembly |
| 3 | Vacuum Pump Bolt
CAUTION:
Refer to Fastener Caution . Procedure Tighten the vacuum pump bolts in the sequence shown. Tighten 25 N.m (18 lb ft) |
| 4 | Vacuum Pump Bolts Procedure Tighten the vacuum pump bolts in the sequence shown. Tighten 25 N.m (18 lb ft) |
| 5 | Vacuum Pump Bolt Procedure Tighten the vacuum pump bolts in the sequence shown. Tighten 25 N.m (18 lb ft) |