Installation Procedure
- Position the turbocharger wastegate actuator (2) in place then hand start the fasteners (1).
- Tighten the wastegate actuator fasteners (1) to 25 N.m (18 lb ft).
- Install the turbocharger wastegate actuator arm (2) then install its retainer (1) to securing the actuator arm.
- Connect the charge air bypass valve vacuum tube to the turbocharger wastegate actuator. Refer to Plastic Collar Quick Connect Fitting Service .
- Install the turbocharger heat shield. Refer to Turbocharger Heat Shield Replacement (Front)Turbocharger Heat Shield Replacement (Rear) .
- Install the front compartment front sight shield. Refer to Front Compartment Front Sight Shield Replacement .
CAUTION:
Refer to Fastener Caution .
NOTE:
Ensure that the actuator arm retainer is installed as previously noted.
NOTE:
Ensure the wastegate vacuum connection is fully seated and secure. A poor connection can result in a DTC and lead to misdiagnosis.