Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
P0A2B and P0A31
- Allow the vehicle to cool to ambient temperature by leaving the ignition OFF and not connected to a charger for at least 6 hours.
- Ignition ON, for the appropriate drive motor, observe scan tool hybrid powertrain control module Motor Temperature parameter and motor control module Phase U, V, W Inverter Temperature parameters.
- Verify Motor Temperature and Phase U, V, W Inverter Temperature parameters are within 28°C (50°F) of each other and ambient temperature.
- If any temperature parameters are not within the specified range
Refer to Circuit/System Testing .
- If all temperature parameters are within the specified range
- If any temperature parameters are not within the specified range
- All OK.
P0A2C, P0A2D, P0A32, and P0A33
- Ignition ON.
- Verify appropriate scan tool motor control module Motor Temperature Sensor parameter is between 0.29-4.42 V.
- If not within the specified range
Refer to Circuit/System Testing .
- If within the specified range
- If not within the specified range
- All OK.