Drive Motor Battery Positive and Negative Cable Replacement
WARNING: This page is about a different variant/trim than selected.
| Callout | Component Name |
|---|---|
|
WARNING:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:
Failure to follow the procedures exactly as written may result in serious injury or death. Preliminary Procedures
|
|
| 1 | Drive Motor Battery Cooling Air Outlet Duct Seal |
| 2 | Drive Motor Battery Cable Terminal Nut
CAUTION:
Refer to Fastener Caution
.
Tighten: 5 N.m (44 lb in) |
| 3 | Drive Motor Battery Cable Terminal Nut Tighten: 5 N.m (44 lb in) |
| 4 | Wiring Harness Connector |
| 5 | Drive Motor Battery Positive and Negative (w/Wiring Harness) Cable Assembly Procedure: After the positive and negative cable assembly has been replaced and the re-assembly of the drive motor generator battery, enable the HV system. Refer to High Voltage Enabling . Tip: Remove the retainer from the fan assembly. |