Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover Replacement
WARNING: This page is about a different variant/trim than selected.
| Callout | Component Name |
|---|---|
|
WARNING:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed. Preliminary Procedure: Disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling .The High Voltage Disabling procedure will perform the following tasks:
Failure to follow the procedures exactly as written may result in serious injury or death. |
|
| 1 | Drive Motor Battery Case Upper Cover Bolt (Qty: 21)
CAUTION:
Refer to Fastener Caution
.
Tighten: 8 N.m (71 lb in) |
| 2 | Drive Motor Battery Case Upper Cover Nut (Qty: 5) Tighten: 8 N.m (71 lb in) |
| 3 | Drive Motor Battery Case Upper Cover |
| 4 | Drive Motor Battery Case Front Cover Bolt (Qty: 9) Tighten: 8 N.m (71 lb in) |
| 5 | Drive Motor Battery Case Front Cover Push Rivet |
| 6 | Drive Motor Battery Case Front Cover |
| 7 | Drive Motor Battery Case Right Side Cover Bolt (Qty: 2) Tighten: 8 N.m (71 lb in) |
| 8 | Drive Motor Battery Case Right Side Cover Nut (Qty: 2) Tighten: 8 N.m (71 lb in) |
| 9 | Drive Motor Battery Case Right Cover Procedure: After the covers have been replaced and the re-assembly of the drive motor generator battery, enable the HV system. Refer to High Voltage Enabling . |