Torque Converter Housing with Fluid Pump Removal

Fig 1: View Of Torque Converter Housing Assembly & Components
GM1696420Courtesy of GENERAL MOTORS CORP.
Torque Converter Housing with Fluid Pump Removal

Callout Component Name
Preliminary Procedure: 
 
NOTE: The valve body assembly must be removed prior to removing the torque converter (with fluid pump) housing assembly. Failure to ensure this will cause severe damage to both fluid pump seal assemblies. Also, the load of the valve body pushing on the seals, which in turn push on the pump, may prevent proper pump installation into the case.
1 Turbine Shaft (O-ring) Seal
2 Bolt M10 x 50 (Quantity: 9)
3 Torque Converter (With Fluid Pump) Housing Assembly
4 Fluid Pump Seal