Method B
WARNING: This page is about a different variant/trim than selected.
To measure bearing clearance using Method B, use the following procedure:
- Clean the used bearing inserts.
- Install the used bearing inserts.
- Place a piece of gaging plastic across the entire bearing width.
- Install the bearing caps.
- Install the bearing cap bolts to specification.
- Remove the bearing cap, leaving the gaging plastic in place. It does not matter whether the gaging plastic adheres to the journal or to the bearing cap.
- Measure the gaging plastic at its widest point with the scale (1) printed on the gaging plastic package.
- Remove the gaging plastic.
CAUTION:
In order to prevent the possibility of cylinder block or crankshaft bearing cap damage, the crankshaft bearing caps are tapped into the cylinder block cavity using a brass, lead, or a leather mallet before the attaching bolts are installed. Do not use attaching bolts to pull the crankshaft bearing caps into the seats. Failure to use this process may damage a cylinder block or a bearing cap.
NOTE:
Do not rotate the crankshaft.