Method A
WARNING: This page is about a different variant/trim than selected.
NOTE:
Do not mix inserts of different nominal size in the same bearing bore.
To measure bearing clearance using Method A, use the following procedure:
- Measure the crankshaft bearing journal diameter with a micrometer (1) in several places, 90 degrees apart. Average the measurements.
- Measure the crankshaft bearing journal taper and runout.
- Install the lower crankcase and tighten the bearing cap bolts to specification.
- Measure bearing inside diameter (ID) in several places 90 degrees apart, average measurements.
- Subtract journal measurement from bearing ID measurement to determine clearance.
- Determine whether clearance is within specification.
- If out of specification, choose different inserts.
- Measure the connecting rod inside diameter in the same direction as the length of the rod with an inside micrometer.
- Measure the crankshaft main bearing inside diameter with an inside micrometer.