Test Description
WARNING: This page is about a different car, the 2006 Buick LaCrosse and 2006 Buick Allure. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers on the diagnostic table.
- 3: This step tests for the proper operation of the circuit in the low voltage range.
- 4: This step tests for the proper operation of the circuit in the high voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to ground.
- 5: This step tests for a short to voltage in the 5-volt reference circuit.
DTC P0530, P0532 or P0533
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views |
||||
| 1 | Did you perform the Diagnostic System Check - Vehicle? | - | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
| 2 |
|
0.2-4.88 V | Go to Diagnostic Aids | Go to Step 3 |
| 3 |
|
0.2 V | Go to Step 4 | Go to Step 10 |
| 4 |
|
4.88 V | Go to Step 5 | Go to Step 8 |
| 5 |
|
5.5 V | Go to Step 6 | Go to Step 7 |
| 6 |
|
5 Ω | Go to Step 12 | Go to Step 11 |
| 7 | Test the 5-volt reference circuit of the A/C refrigerant pressure sensor for short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 16 | Go to Step 13 |
| 8 | Test the 5-volt reference circuit of the A/C refrigerant pressure sensor for a short to ground, a high resistance or an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 16 | Go to Step 9 |
| 9 | Test the signal circuit of the A/C refrigerant pressure sensor for a short to ground, a high resistance or an open. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 16 | Go to Step 13 |
| 10 | Test the signal circuit of the A/C refrigerant pressure sensor for a short to voltage. Refer to Circuit Testing
and Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 16 | Go to Step 13 |
| 11 |
|
- | Go to Step 16 | Go to Step 13 |
| 12 | Inspect for poor connections at the harness connector of the A/C refrigerant pressure sensor. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 16 | Go to Step 14 |
| 13 | Inspect for poor connections at the harness connector of the ECM/PCM. Refer to Testing for Intermittent Conditions and Poor Connections
and Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 16 | Go to Step 15 |
| 14 | Replace the A/C refrigerant pressure sensor. Refer to Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
in Heating, Ventilation and Air Conditioning. Did you complete the replacement? |
- | Go to Step 16 | - |
| 15 | Replace the ECM/PCM. Refer to Control Module References
in Computer/Integrating Systems for replacement, setup and programming. Did you complete the replacement? |
- | Go to Step 16 | - |
| 16 |
|
- | Go to Step 2 | System OK |