Remove expansion valve
CAUTION:
Refrigerant circuit under high pressure
.
Injury hazard!
Injury hazard!
- Note and follow safety instructions on containers.
- Avoid contact with refrigerant; wear safety goggles and hand protection.
- For additional information see: SAFETY INSTRUCTIONS FOR HANDLING TETRAFLUORETHANE REFRIGERANT R134A , or INSTRUCTIONS FOR HANDLING R1234YF REFRIGERANT and NOTES FOR REPAIR WORK ON AIR CONDITIONING .
Preliminary work
- Refer to SUCTION THE AIR CONDITIONING .
- Refer to REMOVING THE ACOUSTIC COVER .
- Refer to REMOVING THE HOLDER FOR THE CABLE TENSION RELIEF .
- Refer to DISCONNECTING THE REFRIGERANT LINE FROM THE EXPANSION VALVE .
- Loosen screws (1).
- Remove the expansion valve (2).