Disconnect the refrigerant line from the expansion valve
CAUTION:
Residual pressure in the heating and air conditioning system
.
Injury hazard!
Injury hazard!
- Wear safety goggles and protective gloves when disconnecting the refrigerant line.
- Close the refrigerant lines with seal plugs.
NOTE:
The following step(s) must be performed if the listed component(s) is/are installed.
- Open the holder (1).
- Remove refrigerant line from the holder (1) and set it aside.
- Open the holder (1).
NOTE:
Schematic diagram is for example purposes. Some parts may differ in certain details.
- Loosen nut (1).
- Remove the refrigerant line (2).