Connecting the coolant hose of the low-temperature coolant circuit
- Check the sealing rings (1) of the coolant lines (2) for damage and replace them if necessary.
- Connect the coolant line (1) and lock audibly.
Follow-up work
- Install RESONATOR .
- Fill the LOW-TEMPERATURE COOLING SYSTEM with the vacuum fill equipment.
- Vent the LOW-TEMPERATURE COOLING SYSTEM .
- Check LOW-TEMPERATURE COOLING SYSTEM for water tightness.
- Install the center UNDERBODY PROTECTION .
- Install the front UNDERBODY PROTECTION .