Installing holder of the DME control unit for cylinders 5 to 8
- Carefully push the holder of the refrigerant line (3) aside.
- Insert holder with the DME control unit of cylinders 5 to 8 (2) and position.
- Engage the connector bracket (1).
- Ensure that the centering pin (2) is located in the lug (1) on the left spring support.
- Engage the cable bracket (1).
- Tighten down screw (2).
TIGHTENING TORQUES SPECIFICATION
| DME control unit holder | ||
| screw | Tightening torque | 8 Nm |
- Tighten the screws (1).
TIGHTENING TORQUES SPECIFICATION
| DME control unit holder | ||
| screw | Tightening torque | 8 Nm |
- Connect connectors (1) and lock.
- Engage the cable bracket (2) in the adapter plate.
Follow-up work
- Refer to INSTALLING THE COVER PANEL OF THE SLAVE DME CONTROL UNIT .
- Refer to CONNECTING BATTERY GROUND LEAD .