Home >> BMW >> 2021 >> 745e xDrive >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> Cooling System -- Repair (1 Of 2) (G12) >> 17 00 Coolant >> 17 00 011 Drain and top up the low-temperature coolant circuit (740e xDrive PHEV 2017-2019) >> Drain the coolant from the low-temperature cooling system

Drain the coolant from the low-temperature cooling system

WARNING: High-voltage system.
The high-voltage system operates on the basis of hazardous, electrical voltage and high currents. Mortal hazard through electric shock!
WARNING: Hot surfaces. 
Risk of burning! 
  • Perform all work only on components that have cooled down.
WARNING: Hot fluids. 
Risk of scalding! 
  • Conduct all work in the vehicle wearing appropriate personal protective equipment only.
WARNING: Working on 12 V electrical system. 
Risk of short circuits! Risk of fire! 
  • Make sure that there is no charger  connected to the jump start terminal in the engine compartment.
  • Detach battery ground lead from battery.
  • For auxiliary batteries: Detach battery minus cables from all auxiliary batteries.
CAUTION: Materials harmful to health. 
Contact with fluids harmful to health! 
  • Note and follow safety instructions on containers.
  • Conduct all work in appropriate personal protective equipment only.
NOTE: TECHNICAL INFORMATION 
Filling without  the vacuum filling equipment (watering can filling) is not permitted  .
If this is not observed, there is a risk of component damage or engine damage.
The filling specification must  be observed.
It is essential to visually check the vacuum filling equipment before use  to check that it is functioning correctly and clean.
It is not permissible to operate the vehicle if the filling procedure has not been fully completed. Otherwise there may be functional limitations (degradation) or overheating.
A bleeding procedure is required after a part has been exchanged in the cooling system and/or after refilling the cooling system.
NOTE: TECHNICAL INFORMATION 
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.

Preliminary work 

WARNING: Hot surfaces. 
Risk of burning! 
  • Perform all work only on components that have cooled down.
CAUTION: Overheating of the high-voltage system. 
Risk of fire! Injury hazard! 
  • If the low-temperature coolant circuit is empty, de-energize the high-voltage system.
  • Drain the coolant only when the high-voltage system has been de-energized.
NOTE: TECHNICAL INFORMATION 
Immobilization period-long fill of coolant! 
Do not reuse used coolant.
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be emptied and refilled.
In the case of other removal work involving the draining of part quantities of coolant, the coolant level must be topped up with new coolant.
NOTE: TECHNICAL INFORMATION 
Collect and dispose of emerging fluids. Observe country-specific waste disposal regulations.
G14214660Courtesy of BMW OF NORTH AMERICA, INC.

Follow-up work