61 35 179 Replacing and installing (replacing) the solar rain/light sensor and condensation sensor
Necessary preliminary tasks:
- Remove INTERIOR MIRROR
Removal:
Disconnect connector (1).
Unlock the rain/light/solar and condensation sensor (2) from the metal spring (3).
To do so, compress the metal spring (3) from both sides, insert a screwdriver (4) from the side and lift the latch mechanism.
Risk of damage.
After loosening lock, wait approx. 30 min. at 20°C for silicone surface to relax.
Pull the rain/light/solar and condensation sensor (1) slowly from holder (2) in direction of arrow.
Pull off the rain/light/solar and condensation sensor (1) slowly while observing from outside the release of the silicone surface.
The silicone surface must evenly loosen from the windscreen, if applicable, pull off slower.
Risk of damage.
The silicone-coated surface (1) and the printed circuit board (2) on the rain/light/solar and condensation sensor must not be touched or damaged.
When replacing the windscreen, immediately install the rain/light/solar and condensation sensor into the new windscreen following removal.
Risk of damage.
The surface (1) on the windscreen must not be touched or damaged.
The separating oil of the rain/light/solar and condensation sensor might have left easily removable residues in the area (1).
This is not considered a damage of the rain/light/solar and condensation sensor.
Remove all residues of the separating oil inside and outside the area (1).
Replacement:
Carefully clean the windscreen at the contact area (1) with the rain/light/solar and condensation sensor. All residues of silicone and separating oil need to be removed.
Remove protective cover (1) from new rain/light/solar and condensation sensor.
The silicone-coated surface (1) and the printed circuit board (2) on the rain/light/solar and condensation sensor must not be touched or damaged.
Installation:
Risk of damage.
The silicone-coated surface on the rain/light/solar and condensation sensor must not be touched or damaged.
Feed the rain/light/solar and condensation sensor (1) into holder (2) in direction of arrow.
Installation note:
Connect connector (1) only after the rain/light/solar and condensation sensor has been locked.
Press on the rain/light/solar and condensation sensor (2) at the metal spring (3) in a centered position.
To lock, consecutively press down both sheet metal tabs (4) on each side.
Connect connector (1) with the rain/light/solar and condensation sensor (2).
Installation note:
Visible shades (1 and 2) do not have any air pockets, but show the optical element of the sensor.
Visible shades (1 and 2) do not represent any functional limitation.
- Initialization and encoding are performed automatically by BDC control unit.
Required reworking:
- Remove INTERIOR MIRROR