LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2017 >> X6 sDrive35i >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> Cooling System -- Repair X6 (F16) >> 17 11 Engine Oil Cooler With Attachment >> 17 11 035 Removing and installing/replacing the fan cowl with electric fan (N63) (X6 xDrive 50i)

17 11 035 Removing and installing/replacing the fan cowl with electric fan (N63) (X6 xDrive 50i)

Necessary preliminary work: 

Unclip Bowden cable for engine compartment lid operation from transverse reinforcement.

Release screws (1). Replace screws.

Tightening torque 17 10 4AZ .

Remove transverse reinforcement (2).

G11104174Courtesy of BMW OF NORTH AMERICA, INC.

Release coolant hose (1) from fan cowl.

G11104756Courtesy of BMW OF NORTH AMERICA, INC.

Unlock connector (1) and remove.

G11104757Courtesy of BMW OF NORTH AMERICA, INC.

Press lock (1).

Raise fan cowl (2) until holder (3) can be folded into center of vehicle.

NOTE: For reasons of clarity, graphic and text show coolant hose removed.
Do not raise fan cowl by fan wheel.
G04794054Courtesy of BMW OF NORTH AMERICA, INC.

Press lock (1).

Feed out fan cowl (2) towards top and remove.

G04794055Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

Insert retaining tab (1) at bottom on module carrier.

G04794056Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Check stored fault message.
Reassemble the vehicle.
Clear diagnostic fault entries from fault memory.