Replacing the auxiliary coolant pump for stationary/auxiliary heating (X5 M)
Special tools required:
- 13 3 010
WARNING:
Risk of burning!
Repair work on the cooling system may only be carried out when it has cooled down.
Repair work on the cooling system may only be carried out when it has cooled down.
Recycling
Coolant emerges when coolant lines are detached. Have a suitable collecting vessel ready.
Catch and dispose of emerging coolant.
Observe country-specific waste disposal regulations.
Necessary preliminary work:
- Remove LEFT FLOOR ASSEMBLY COVER .
NOTE:
Clamp off COOLANT HOSES
.
Disconnect coolant hoses (1) with special tool 13 3 010 and release relevant hose clips.
Release screw (2).
Pull off the auxiliary coolant pump (3) and disconnect the associated plug connection.
Tightening torque 64 12 3AZ .
After installation:
- Fill and vent COOLING SYSTEM and check for leaks.