64 53 551 Removing and installing/replacing capacitor (with desiccant insert) for heating and air conditioning system
Special tools required:
- 00 9 030
WARNING:
Danger of injury!
Refrigerant circuit is under high pressure!
Avoid contact with refrigerant and refrigerant oil.
Read and comply with safety information:
Refrigerant circuit is under high pressure!
Avoid contact with refrigerant and refrigerant oil.
Read and comply with safety information:
- Refer to applicable instructions and safety information for handling refrigerant:
- Follow safety instructions for HANDLING REFRIGERANT OIL .
Attention!
Risk of damage!
Restart engine only when air conditioning has been correctly filled.
Follow INSTRUCTIONS FOR OPENING AND REPLACING PARTS IN REFRIGERANT CIRCUIT .
NOTE:
Desiccant insert cannot be replaced separately.
Necessary preliminary work:
- Drain off AIR CONDITIONING SYSTEM
- Remove RADIATOR
Release screws (1).
Pull out refrigerant lines (2) from condenser (3) and set aside.
Tightening torque: 64 53 3AZ .
Release screw (4).
Remove condenser (3) in direction of arrow.
Installation note:
The fins on the radiator and condenser should not be damaged.
Replace sealing rings.
Use special tool 00 9 030 to install sealing rings without damaging them.
After installation: