LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2014 >> M6 2D Convertible, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 92 (Intake Plenum, Turbocharger, Vacuum Pump, EGR Valve, Oxygen Sensors - Repair) >> Oxygen Sensors >> 11 78 543 Replacing right monitoring sensor (N63O1)

11 78 543 Replacing right monitoring sensor (N63O1)

WARNING: This page is about a different variant/trim than selected.

Special tools required: 

WARNING: Risk of burning! 
Only perform repair work after engine has cooled down.

Necessary preliminary tasks: 

Release retaining clip (1).

Remove heat shield (2) over oxygen sensor.

Detach oxygen sensor cable from retaining clips (3).

Graphic N63.

Fig 1: Identifying Wire Ring And Retaining Clip
G06178811Courtesy of BMW OF NORTH AMERICA, INC.

Release monitoring sensor (1) with special tool 11 7 020 .

Graphic N63.

Fig 2: Releasing Monitoring Sensor Using Special Tool (11 7 020)
G06178832Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

The threads of new oxygen control/monitoring sensors are already coated with NEVER-SEEZ COMPOUND .

If a lambda control/monitoring sensor is to be reused, apply a thin and even coating of Never-Seez Compound to the thread only.

The part of the lambda control/monitoring sensor which projects into the exhaust branch (sensor ceramics) must not  be cleaned and not  coated with lubricant.

Fasten monitoring sensor (1) with special tool 11 7 020 .

Tightening torque 11 78 1AZ .

Fig 3: Releasing Monitoring Sensor Using Special Tool (11 7 020)
G06178832Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

Check function of DME control unit.

Pay attention to cable routing of monitor sensor.