Fault description
Diagnosis monitors whether the intake air temperature (from HFM), cylinder bank 1, is implausibly low.
The fault is detected when the temperature is more than 18 K below the minimum from the coolant and ambient temperature.
Possible cause of fault:
- Stuck sensor
- Shunt
- Sensor manipulation