Action in service
- Measure the voltage at one of the sensors or actuators connected to 5V output 3 of the DME (see applicable wiring diagram).
If measured voltage is above 5.2 V there is a short circuit to B+:
Check cable harness between 5V output 3 of the DME and the sensors or actuators connected to it.
If measured voltage is less than 4.8 V:
One by one, disconnect the sensors or actuators connected to the 5 V output 3 of the DME and measure voltage; if the voltage reading goes to 5 V replace the sensor in question.
- Replace DME.