Action in service
Consequential fault, rectify faults relating to the following components or functions:
- Mixture control
- Variable camshaft timing control
- Tank ventilation
- Ignition
- Injection system
- Crankshaft sensor
- Camshaft sensor
- Electromotive throttle actuator
- Hot-film air mass meter
Check lines and plug connections between the following components:
- DME
- Oxygen sensor before catalytic converter
Check whether the oxygen sensors before and after the catalytic converter have been mixed up.
Check crankcase ventilation.
Replace oxygen sensor before catalytic converter.