Condition for fault identification
Temperature related-precondition:
The following applies for B38:
Oil temperature model value in the range between lower and upper threshold.
Lower threshold -9.76 °C
Upper threshold 143.24 °C
Following applies to all other versions:
- Coolant temperature greater than 80 °C
Time related-precondition:
- None
Other preconditions:
- Engine running.
Control unit voltage: 9 V to 16 V.
Terminal 15 on