LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2013 >> Z4 28i, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 1356 (Engine - Repair (N54) -- Z4_E89) >> 1178 emission control, oxygen sensor >> 11 78 513 Replacing both oxygen control sensors (N54, N54T)

11 78 513 Replacing both oxygen control sensors (N54, N54T)

WARNING: This page is about a different car, the 2016 BMW Z4, 2015 BMW Z4, and 2014 BMW Z4. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

WARNING: Risk of burning! 
Work should only be carried out on an exhaust system that has cooled down.

Necessary preliminary tasks: 

NOTE: It is not necessary to conduct a chassis/wheel alignment check when the track rod is released.

Installation note: 

If an oxygen sensor is reused, only apply a thin and uniform coat of Never Seez Compound (refer to BMW Parts Service) to thread.

The part of the oxygen control sensor which projects into the exhaust system branch (sensor ceramic) must not be cleaned or come into contact with lubricant.

Remove protective plate over steering gear.

Release screws (1) and remove protective plate (2).

Fig 1: Identifying Oxygen Control Sensor Protective Plate And Screws
G06904443

Disconnect plug connection for oxygen control sensor, cylinders 1 to 3.

Release oxygen control sensor (1) with special tools 11 7 030 and 11 9 150 .

IMPORTANT: When using special tool 11 7 030 in conjunction with special tool 11 9 150 , it is essential to reduce the prescribed tightening torque by 3 Nm.

Tightening torque 11 78 1AZ .

Installation note: 

Cable colour black, cylinders 1 to 3.

Fig 2: Removing Oxygen Control Sensor Using Special Tools (11 7 030) And (11 9 150)
G04755076

Disconnect plug connection for oxygen control sensor, cylinders 4 to 6.

Release oxygen control sensor (1) with special tools 11 7 030 and 11 9 150 .

IMPORTANT: When using special tool 11 7 030 in conjunction with special tool 11 9 150 , it is essential to reduce the prescribed tightening torque by 3 Nm.

Tightening torque 11 78 1AZ .

Installation note: 

Cable colour grey, cylinders 4 to 6.

Fig 3: Removing Oxygen Control Sensor Using Special Tools (11 7 030) And (11 9 150)
G04755077

Assemble engine.

Check function of DME control unit.