65 50 170 Replacing the cover for the Central Information Display (CID) (as of 10/2009)
IMPORTANT:
Read and comply with notes on protection against electrostatic damage (ESD PROTECTION
).
Necessary preliminary work:
Remove Central Information Display
Release screws (1). Tightening torque 5.5 INCH lbs. (63 N.m). Note: To tighten screws, use special tool 00 9 460.
IMPORTANT:
Risk of damage !
Carefully unlock latch mechanisms (1) with a suitable tool. Remove cover (2) from Central Information Display (3).
IMPORTANT:
Before/after assembly, cover is bolted to the Central Information Display, correct installation position must first be checked!
Installation note: Before connecting the screw connection, check whether latch mechanisms marked with an arrow are correctly seated.
Installation note: Before connecting the screw connection, check all-round rim at the places marked with an arrow.