Fault description
Diagnosis monitors the internal resistance of the oxygen sensor 2 after catalytic converter.
The fault is detected when the internal resistance of the oxygen sensor 2 after catalytic converter is greater than 5000 Ohm.
Possible cause of fault:
- Contact resistance in connector of oxygen sensor
- Oxygen sensor after catalytic converter cooled down too much due to external influence (e.g. icing)
- Wiring harness of oxygen sensor after catalytic converter defective
- Oxygen sensor after catalytic converter defective (heater defective)