Fault description
Diagnosis monitors the sensor voltage also in overrun mode.
The fault is detected when the sensor voltage is less than 2.1 V during overrun mode.
Possible cause of fault:
- Wiring harness of oxygen sensor before catalytic converter defective
- Oxygen sensor before catalytic converter defective