Fault description
Diagnosis monitors whether the signal from the charge air temperature sensor, cylinder bank 1, is too high.
The fault is detected when the charge air temperature is 24 K above the coolant temperature and the ambient temperature close to the coolant temperature.
Possible fault cause:
- Manipulation of the sensor signal, shunt on sensor