64 11 827 Replacing actuator drive for outer left ventilation flap
WARNING: This page is about a different car, the 2011 BMW 750xi, 2011 BMW 750Lxi, 2010 BMW 750xi, and 2010 BMW 750Lxi. However, it is still accessible from the selected car via links, so may be relevant.
Necessary preliminary tasks:
- Remove INSTRUMENT PANEL TRIM
Position of actuator drive:
OVERVIEW OF ACTUATOR DRIVES ON HEATING AND AIR-CONDITIONING UNIT
Release screws (1).
Remove servomotor (2) and unlock and disconnect plug connection (3).
Replacement:
Servomotors must be readdressed in the event of replacement!
Addressing can only be carried out with the BMW diagnosis system.
Service functions:
- Body
- Heating and air conditioning function
- Flap motors
- Readdress flap motors