67 62 000 Removing and installing or replacing flat motor for front left or right power window unit

Necessary preliminary tasks 

Release screws (1) and detach flat motor (2) from power window unit.

Installation: 

Retaining pins (3) must not be released!

Fig 1: Identifying Power Window Unit Flat Motor, Mounting Screws And Pins
G06214006Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: To ensure tension-free installation of flat motor, observe the specified screwing sequence without fail.

Tighten first screw (1), then screw (2) and finally screw (3).

Tightening torque 67 62 1AZ .

Fig 2: Identifying Power Window Unit Flat Motor Mounting Screws
G06214007Courtesy of BMW OF NORTH AMERICA, INC.

After installation 

A normalization must be carried out in order to activate anti-trapping protection.

Normalization sequence:

NOTE: If normalization is unsuccessful or the power window unit malfunctions, it will be necessary to carry out normalization via the control unit functions in the diagnosis system.