67 62 000 Removing and installing or replacing flat motor for front left or right power window unit
Necessary preliminary tasks
- Remove SOUND INSULATION IN FRONT DOORS .
- Remove FRONT SECTION OF POWER WINDOW UNIT .
Release screws (1) and detach flat motor (2) from power window unit.
Installation:
Retaining pins (3) must not be released!
IMPORTANT:
To ensure tension-free installation of flat motor, observe the specified screwing sequence without fail.
Tighten first screw (1), then screw (2) and finally screw (3).
Tightening torque 67 62 1AZ .
After installation
A normalization must be carried out in order to activate anti-trapping protection.
Normalization sequence:
- Ensure adequate system voltage.
- All doors closed.
- Press correspond power window switch in "Close" position and hold for approx. 2 seconds with window closed.
NOTE:
If normalization is unsuccessful or the power window unit malfunctions, it will be necessary to carry out normalization via the control unit functions in the diagnosis system.
- Front power window: Footwell module.
- Rear power window: Junction box.