Condition for fault identification
Test condition:
The fault is recognized when the mixture for one cylinder must be corrected by more than +/- 15 %.
Potential problem source(s):
- Defective injector
- Oxygen sensor defective
- Fuel pressure fluctuates or is consistently too high or too low
- Defective wastegate control
- Exhaust backpressure too high
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- from - 10 °C to normal operating temperature
Time condition:
- None
Other conditions:
- v > 90 km/h
- Highest gear