Condition for fault identification
Test condition:
The fault is recognized when the reported temperature is > 136 °C.
Potential problem source(s):
- Engine overheats
- Defective water pump
Terminal condition: Terminal 15
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- No BSD fault