Condition for fault identification
Test condition:
The fault is recognized when the accelerator pedal and the brake pedal have been depressed simultaneously for a specific period.
Potential problem source(s):
- Operator error: Continuous, simultaneous pressure on accelerator and brake pedal
- Sticking accelerator pedal
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- Speed > 10 km/h