Condition for fault identification
Test condition:
The fault is recognized when the speed signal is 0 km/h although other operating conditions indicate that the vehicle is moving.
Potential problem source(s):
L4 Wheelspeed sensor at left front, wire or EHB3 is defective
L6 FlexRay bus fault, ICMQL, DSC, wheelspeed sensors
Terminal condition: none
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- E7X: Mass airflow > 272 mg/stroke; engine speed > 2820 RPM
- F01: Drive torque > 46 Nm; engine speed > 1450 RPM