Condition for fault identification
Test condition:
The fault is recognized when both sensors in the accelerator pedal module are defective.
Potential problem source(s):
- Defect with power-supply voltage to accelerator pedal module
- Accelerator pedal module defective
- Defective DME
Terminal condition: Terminal 15
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none