Condition for fault identification
Test condition:
The fault is recognized when the digital air mass signal is continuously at low level.
Potential problem source(s):
- Signal line: Short circuit to ground
Terminal condition: none
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- Engine on