Condition for fault identification
Test condition:
The fault is recognized when the catalyst diagnosis value rises above 0.92.
Potential problem source(s):
- Catalyst 2 defective
Terminal condition: none
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- Coolant temperature > 70 °C
- Calculated temperature of precatalyst > 380 °C
- Calculated temperature of catalyst > 450 °C
Time condition:
- None
Other conditions:
- Engine on
- Speed between 28 and 109 km/h
- Lambda closed-loop mixture control and trim control = ON
- Engine RPM between 1500 and 3000 RPM