Condition for fault identification
Test condition:
The fault is recognized when the voltage is less than 0.1 V.
Potential problem source(s):
- Defect in wiring harness between DME and sensor
- Sensor defective
Terminal condition: Terminal 15
Voltage condition:
- Electrical system voltage > 9.15 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none