Home >> BMW >> 2011 >> X6 ActiveHybrid >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Diagnostic Trouble Codes (ACTIVEHYBRID) - DTC P0040, BMW DTC 128008 Through DTC P300F, BMW DTC 138904 >> DTC P2197, BMW DTC 128201: Oxygen sensor before catalytic converter 2, system check: Signal, constantly lean >> Condition for fault identification

Condition for fault identification

Test condition:

The fault is recognized when the monitored lambda is too lean by a factor of 0.09 relative to the specified lambda excess-air factor.

Potential problem source(s):

Terminal condition: none

Voltage condition:

Temperature condition:

Time condition:

Other conditions: