Home >> BMW >> 2011 >> X6 ActiveHybrid >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Diagnostic Trouble Codes (ACTIVEHYBRID) - DTC P0040, BMW DTC 128008 Through DTC P300F, BMW DTC 138904 >> DTC P112C, BMW DTC 128E04: Oxygen sensor before catalytic converter, line fault: Open circuit, virtual earth or pump power supply line >> Condition for fault identification

Condition for fault identification

Test condition:

The fault is recognized when the sensor voltage is higher than 1.899 V and less than 2.1 V or less than 2.1 V in overrun mode.

Potential problem source(s):

Terminal condition: none

Voltage condition:

Temperature condition:

Time condition:

Other conditions: